ibm 3584 error codes. 194: X'C2' X'08' OPEN: It was attempted to open the data component of a compressed cluster for output, or to open the index component of a compressed cluster. ibm 3584 error codes

 
 194: X'C2' X'08' OPEN: It was attempted to open the data component of a compressed cluster for output, or to open the index component of a compressed clusteribm 3584 error codes  If you want to have them turn on a trace for a Managed MQ Client fro NuGet you need to follow the Using the stand-alone IBM MQ

- A job or job step return code can only be a remainder of a value divided by 4096. config file that tells it turn turn on the trace. 56 ft) fibre drive cable that was shipped with each drive. . (As example of above password in RED. 3584 Tape Library IBM Support. The maintenance of the AC units is the responsibility of Pentair. 0. e. 48L (BPET48L) firmware for the Advanced Management Module is. Each aspect of the subsystem is designed to optimize access to data and reliability. com, a global distributor of electronics components. Inventories, audits and calibrations have also been run on the 3584 to no avail prior to the tapes being removed. Tape device encryption provides. The IBM TS3500 Command Line Interface (CLI) program can be used to access the TS3500 library from a CLI. The IBM 3584 TS3500 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange to high-end systems. Return codes indicate the general types of conditions and might be coupled with reason codes that further qualify these conditions. IBM Documentation. Specifications. Explanation During an operation with the device, the TS7700 Engine determined that the device is not operating correctly and requires service. System action. g. The IBM TotalStorage 3584 Tape Library Expansion Frame 3584 Model D22 may be added to the IBM TotalStorage 3584 Tape Library Base Frame Models L22, L32, or L52 in order to add storage or drive capacity. Examine gsk_status code (returned as the reason code), which are documented in z/OS Cryptographic Services System SSL Programming. So does look like it was a false possitive as you said above. Gripper {GRIPPER} encountered a low current condition while retracting. Message-text can be up to 240 characters in length. Examine gsk_status code (returned as the reason code), which are documented in z/OS Cryptographic Services System SSL Programming. You need the following information about the Kerberos server to be able to run the command. This 18th edition includes information about the latest IBM Linear Tape-Open (LTO) Ultrium 9 tape drive, IBM TS4500 tape library, IBM TS4300 tape library, TS2900 tape autoloader, along with technical information about each IBM tape product for open systems. Each time the library door is closed, a bar code reader mounted on the autochanger scans the cartridge labels enabling a re-inventory of the cartridges in. If you want to have them turn on a trace for a Managed MQ Client fro NuGet you need to follow the Using the stand-alone IBM MQ . Now this support has been extended to also cover TS3500 (3584) with 3592-E05 and 3592-E06 drives. This document contains a list of IDC codes, their description, and troubleshooting tips, for Datacap Navigator. Because. Use Priority/Reference Code: YE001 Phone: 800-IBM-CALL Fax: 800-2IBM-FAX Internet: [email protected] IBM 3584 UltraScalable Tape Library is a high-performance, reliable, scalable tape library subsystem, designed for tape automation. Please let. Discovery is not creating a storage system or providing any other info outside of DeviceInfo. Supported SCSI Commands An introduction to the SCSI commands that are recognized by the TS3500 tape library. Failure ID (FID) messages are short codes that can be used by service technicians to isolate problems with the 3592 tape drive. We have had a couple of service calls throughout the year, but nothing like with the 3494. Overview The IBM 3584 UltraScalable Tape Library provides a highly scalable, automated tape repository combining proven IBM automation technology and high-performance IBM LTO Ultrium tape drives for the mid-range to. In conjunction with a service bay feature on the 3584 Model D22 or D52, the Model HA1 provides for the installation and operation of a second library accessor in a 3584 Tape Library to help. For example, enter "-105" instead of -105 in the search field. Power cycle the library. Record the error message and any error codes. The 3584 is designed to be a highly scalable, automated tape library combining IBM automation technology for midrange to enterprise environments. 5. The name of the step in the procedure. If you like, I have a copy of Maintenance guide for 3584, that i can send you a pdf copy of (+700 pages) - just let me know. Use a known good tape cartridge in the suspect drive. RE: IBM LTO FSC CODES itsp1965 (IS/IT--Management) 10 Jun 09 09:08. Each time the library door is closed, a bar code reader mounted on the autochanger scans the cartridge labels enabling a re-inventory of the cartridges in. Status lights (FC 5638) You might need to read the status lights on your tape drive to determine the operating status of the drive. The license is also part of the IBM® Database Enterprise Developer Edition. 5 sp4 on windows 2003 sp2 We recently updated our ibm ts3584 library's firmware level to 7420. Miniboot-1 codes: This class of return code arises from the replaceable POST and code-loading code. TS1060 - IBM 3584 (TS3500) LTO-6 FC Tape Drive In Stock. The IBM 3584 TS3500 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange to high-end systems. However, IBM service must be present during the maintenance to ensure that the TS4500 is not harmed/interrupted by AC maintenance. Press BACK until you return to the Activity screen from step 1. 0. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. In a multiple installation environment, where an application attempts to connect to a queue manager associated with an installation of IBM WebSphere® MQ 7. LDAP_TYPE_OR_VALUE_EXISTS. Our 3584 is 7-frames (1-L23 + 6-D23) with 17 TS1130 E06 drives. The 3584 Tape Library supports the IBM TotalStorage LTO. 530 A problem with one of the node's power supplies has been detected. jcc. Front view of a half-high LTO tape drive. The TS3200 has a 48-tape cartridge capacity and contains up to two LTO. Feature codes for elements in the library. The NMA state is a condition set as a result of an accessor detecting an apparent obstruction to normal accessor movement. Once was a known firmware problem. YE001 P. The 3584 Tape Library supports the IBM TotalStorage LTO. in the hardware, box, enclosure and rack accessories category. In conjunction with a service bay feature on the 3584 Model D22 or D52, the Model HA1 provides for the installation and operation of a second library accessor in a 3584 Tape Library to help. ch' See here. Table 1. Each aspect of the subsystem is designed to optimize access to data and reliability. Hi does anyone have a definitive list of the FSC codes with descriptions for the IBM LTO? Appreciate any help. Use this table only if no sense data is available. IBM TS1170 tape drives are able to RW 50TB capacities on JF media. This is in addition to the TS3500’s Web Specialist. Model abstract 3584-D42. IBM's 3584-D55 is a 3584 ts4500 tape library model. HYDIN0112W (OP0112) Device. # step 1 - enable an instance policy, which prevents creating standard keys $ curl -X PUT ". The scheduler assigns error codes to certain operations and to job and started task steps. Attempt to create a standard key, which fails. It is a full field perspective, and as such, a customized recommendation which takes into account specifics such as business upgrade windows, length of time since last update, decommission plans, etc. If the server system is a Db2 for z/OS server, a DSNL030I message at the server system describes the cause. Bookmark. The IBM TotalStorage 3584 High Availability Frame Model HA1 may be added to the IBM TotalStorage 3584 Tape Library Base Frame Models L22, L32, or L52. It includes a five-character message ID field that can be examined by message automation software to filter or route specific messages. __ 2. clu). This IBM Redbooks® publication gives you a close-up view of the new IBM TS4500 tape library. Hi All, We re running TSM 6. SNMP finds IBM 3584 tape library. Model abstract 3584-D42. Subject: Re: [ADSM-L] TS3500 firmware/hardware issues. ECSFBEXT (10005) The high-order 16 bits of the reason code represent the. 215. The condition codes that are tested in the IF-THEN-ELSE command sequence are: 0. An abend may have occurred within the step, but if it did and this message IEF142I is issued, it indicates that an ESTAE suppressed the abend and that the step itself terminated normally. SCSI Interface Cables (Various Layouts) 196 IBM System Storage TS3500 Tape Library 3584 Maintenance Information (27th Edition, 2013) Note: If you are not installing any fibre drive trays, go to “SCSI Cabling (Trays)” on page 198. 523 The internal disk file system is damaged. Use a known good tape cartridge in. com, a global distributor of electronics components. Connect one end of the DB9F to DB9F Null Modem cable (P/N 19P4693) to port 1 on the WTI. This will usually shed more light on. 4. VERFINAL specific return and reason codes. If the response file you specify in the command line does not exist or the file name is incorrect, the silent installation process does not write the log files. __ 1. config file that points to a directory where you create a trace. Programmer Response: Ensure the program reestablished the enqueues upon restart. The file is in the /tmp directory and has a time stamp suffix, for example: /tmp/createdb_20131018-131841. Observe the trap when it is received by systems management software and identify its components. YE001 P. 35L1207: 3584: IBM TS3500 – FIC-card – 3584 L32 Frame Interconnect Card: 35L1209: 3584: IBM TS3500 – Redundant EPO Cable – FIC to FIC: 35L1725: 3584: IBM TS3500 – Door Switch Interlock incl. The IBM TotalStorage 3584 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange systems to high-end open systems. Model. Cartridge {VOLSER} could not be unloaded. The codes are four bytes long. 3 running on Windows Server 2003 When you look at the device manager on the server, you see a list of medium changers and a list of tape drives. //Degree/@Degree = "MBA. Cable. am. The 3584 Tape Library supports the IBM TotalStorage LTO. Cannot find MSPsX'08' Request Macros: VSAM encountered an invalid relative-record number. A drive. Machine Model 3584 (TS3500) Part Type Tape Drive. An N in the CRU ID column means that the part is not a CRU. ECSFBEXT (10005) The high-order 16 bits of the reason code represent the. The 3584 Tape Library supports the IBM. This problem happens on z/OS®. 534 System board fault. The continuation might not provide you with exactly what you wanted, but no permanent harm was done. Type or value exists. The support package from each node will be required. (SESSION: 846260, PROCESS: 2560) 02/03/2016 15:16:32 ANR8446W Manual intervention required for library 3584_LTO6. The SQL statement cannot be processed. 3 with Storage. The IBM 3584 TS3500 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange to high-end systems. Model abstract 3584-D32. 6. IBM TS3500 – XCP-card – 3584 L32/22/52: 35L1006: 3584: I/O to I/Ocard cable: 35L1040: 3590: B1x-Head Ass. There was a tape in all 4 drives: this drive was running migration when the power went out. Learn how to install and configure the IBM PowerHA SystemMirror for AIX Standard and Enterprise Editions in this comprehensive guide. No data has been lost, but there has been a reduction in the performance of the tape. For barcode considerations, see LTO barcode tape labels length. 17. Technology Type Tape Storage. A problem occurred in executing the complete function, but it continued. ; 42: 2AH: Drive module is missing or not communicating. Abstract. Appendix G. • Do not use this MI to complete service procedures on a 3592 EH7, EH8, 55F, or 60F drive installed in an IBM TS4500, but refer to the Knowledge Center for that product. IBM TS1170 tape drives are able to RW 50TB capacities on JF media. This severity-impact-text corresponds to what is documented in IBM Whitepaper, IBM TS7700 Series Operator Informational Messages, for the reported message number from the TS7700. BIND ERROR, ATTEMPTING TO REPLACE PACKAGE = package_name WITH version= version2 BUT THIS VERSION ALREADY EXISTS-721 BIND ERROR FOR PACKAGE = pkg-id CONTOKEN = contoken'X IS NOT UNIQUE SO IT CANNOT BE CREATED-722 bind-type ERROR USING auth-id AUTHORITY PACKAGE package-name DOES NOT. Reason Codes for Return Code 8 (8) Reason Code Hex (Decimal) A key identifier was passed to a service or token. Select the Launch Firmware Update Wizard, then select the choice to update a drive. Consider the following points:The TS3100 library uses of one IBM Linear Tape-Open (LTO) Ultrium 7, 6, or 5 Full-High tape drive, or up to two LTO Ultrium 7, 6, or 5 Half-High tape drives. 21. actidata actiTape LTO-5 Half Height Drive ID : IBM ULTRIUM-HH5. If using the IBM Tape Device Driver or ITDT (IBM Tape View and Download IBM 3592 maintenance information online. Warning. The IBM 3584 TS3500 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange to high-end systems. Note: Do not force a new dump; the tape drive has already created one. A drive performed a self-reset. This is an entry tape library incorporating high-performance IBM TotalStorage LTO Ultrium 2 and Ultrium 3 tape drives for the midrange open systems environment. Enter a pathname and do one of these: - Press Enter. Error code syntax. 1 cannot load libraries from other versions of IBM MQ. Some of the most promising codes today are called quantum low-density parity check, or LDPC codes. Some informational messages can be issued. Db2 uses the communications database (CDB) to control network security functions. 2. Attempt to create a standard key, which fails. Each time the library door is closed, a bar code reader mounted on the autochanger scans the cartridge labels enabling a re-inventory of the cartridges in. Shows as SNMP sysDescr IBM 3584 Tape Library. kev009. The IBM 3584 TS3500 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange to high-end systems. If a FID message appears, you must note the. We currently have the ibm 3494 library with 3592-e05 (ts1120) drives. Errors are divided into three categories – data, input, or internal. Scribd is the world's largest social reading and publishing site. To determine if the problem is with the drive hardware, or the tape media, perform the following procedures: If possible, run the tape cartridge in a different drive. The Firmware Update screen displays. Tier 1 CRU: No tools required. On 5/2/2014 14:39, Lee, Gary wrote: [quote]Looking at updating our tape libraries for other rojects which might use ltfs. Table 1. Contact your IBM service. Informational. Unexpected motion of the pivot motor and unexpected activation of the cartridge present sensor are the detection mechanisms. The IBM 3584 TS3500 Tape Library Model D53 expansion frame is designed for IBM TS1030 LTO Ultrium Fibre Channel Tape Drives and LTO data cartridges. IBM TS1170 model 70F with FC interface and model 70S with SAS interface deliver a native data rate of 400MB/s (900MB/s compressed) and are designed to deliver a 250% increase in capacity on the JF media compared to the TS1160 tape drives. The new 3584 Model D22 and D52 Frames can be attached to Model L22 or L52 Frames, or to installed 3584 Model L32 or D32 Frames, and can be intermixed within the same 3584. 215) is the same correct ID +. See Common reference codes for i5/OS software installation for more information. When tapes are placed into the library I still have to Inventory the robot in order to get. com Mail: IBM Atlanta Sales Center Dept. v IBM TS3500 T ape Library with ALMS: Intr oduction and Planning Guide, GA32-0593 v IBM TS3500 T ape Library with ALMS: Operator's Guide, GA32-0594 v IBM TS3500 T ape Library with ALMS: T ape System Reporter User's Guide, GA32-0589 v IBM TS3310 T ape Library Setup and Operator Guide, GA32-0477 v IBM TS3310 T ape Library Maintenance Information. 214 'IBM3584. Each time the library door is closed, a bar code reader mounted on the autochanger is designed to scan the cartridge labels enabling a re-inventory of the. The IBM 3584 TS3500 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange to high-end systems. The 3592 E07 tape drive uses the 3592 Advanced Economy (type JK) cartridge with a maximum capacity of 500 GB (465. The action legend defines the action that is correlated with each action key. If Flag Number 4 is also set, the. Table 1 shows the command format. A drive requested a cleaning. This section provides reference material related to the Small Computer Systems Interface (SCSI) supported by the TS3500 tape library. The system may be any of the following IBM servers: BladeCenter S, Type 8886, any model; The system is configured with one or more of the following IBM Options: IBM BladeCenter S SAS RAID Controller Module, Option 43W3584; This tip is not software specific. The TS3400 Tape Library is an external 5U stand-alone or rack-mountable unit that. For more. So far as I can tell the 3584 seems to be practically a drop-in replacement for the 3494. Get drivers and downloads for your Dell Inspiron 3584. Description. I need to share my IBM 3584 Library between Networker and Veeam 9. The IBM TotalStorage 3584 High Availability Frame Model HA1 may be added to the IBM TotalStorage 3584 Tape Library Base Frame Models L22, L32, or L52. The NMA state is a condition set as a result of an accessor detecting an apparent obstruction to normal accessor movement. See your system programmer. T ypically , all messages for a component have the same pr efix. com Mail: IBM Atlanta Sales Center Dept. conf file of the media server with a TL8 or TLD robotic control daemon, the Media Access Port (MAP) of the robot will be emptied into the robotic library and the volume database will be updated. We have had a couple of service calls throughout the year, but nothing like with the 3494. IBM Spectrum Protect server and client messages format IBM Spectr um Pr otect server and client messages consist of the following elements: v A thr ee-letter pr efix. Search all of IBM. 3 running on Windows Server 2003 When you look at the device manager on the server, you see a list of medium changers and a list of tape drives. On a 3584 (TS3500), it is possible to have the Advanced Library Management System (ALMS) feature enabled. All is working as expected except for Control Path Failover feature. The TS3000 system console (TSSC) provides the same functionality to attach a TS3500 tape library that is connected to an Open Systems server. Gripper {GRIPPER} sensor failed. 1. Page 17: Chapter 1. anthony. The IBM 3584 TS3500 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange to high-end systems. However, IBM service must be present during the maintenance to ensure that the TS4500 is not harmed/interrupted by AC maintenance. Figure 1 shows a sample SNMP trap. Mode Select (6) - X'15'. TS3500 Command Line Interface. The drive dump log provides more info then the BLZ log that you posted. IBM TS3500 Tape Library Maintenance Information, (provided with the 3584 Tape Library); IBM TS3500 Tape Library Introduction and Planning Guide, GA32- How to use the web interface to operate the TS3500 tape library. Solution 2. The IBM TotalStorage 3584 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange systems to high-end open systems. The return code is 200+ nn where nn identifies the function being performed. We have just hit the 1-year mark with our 3584. Remove (disable) the instance policy, which allows creating standard keys. 6. End of Marketing (EOM)Below lines are from ConfigMgrAdminUISetup. Two status light-emitting diode (LED) lights and their ISO symbols appear on the drive as follows: Figure 1. Then, the Mode Select (10) and Mode Sense (10) commands are used to transfer all mode pages. This warning applies only to connections to. The system issues this message to give the condition code from the step. The system issues this message to give the condition code from the step. The Mode Sense (6) command is supported by the tape library. The IBM 3584 TS3500 Tape Library Model D53 expansion frame is designed for IBM TS1030 LTO Ultrium Fibre Channel Tape Drives and LTO data cartridges. This section provides reference material related to the Small Computer Systems Interface (SCSI) supported by the TS3500 tape library. Enhanced format for recording error-correction codes ;. Each aspect of the subsystem is designed to optimize access to data and reliability. //ABND07 EXEC PGM=ABEND,COND= (0,EQ,STEP07) "STEP07" is a DB2 program that might not abend if it has problems and puts out a "bad" condition code. This entry only operates with TL8 or TLD robots that post a unit attention when their MAP has. 3584 Tape Library Operator Guide. A message displays on the TS4500 management GUI and indicates that a front door is open. Discovery version 11. Once was a known firmware problem. A drive reset is recommended. For other firmware levels that are not posted on FixCentral, such as firmware for LTO1 and LTO2 tape drives, the SNMP MIB file, and older library firmware levels, please go to the 3584/TS3500 Tape Library Firmware FTP site. The IBM TotalStorage 3584 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange systems to high-end open systems. Reason Code Return or Abend Code (hex) Meaning; 000: 10: Possible enqueue error. Box 2690 Atlanta, GA 30301-2690 You can also contact your local IBM Business Partner or IBM representative. The Standard Edition (ITDT-SE) is a command line version and it is available for most major platforms (Windows, AIX, Linux, Mac OS X and IBM System I/OS). YE001 P. We. The Control23 mini-conference brings together security and storage experts to share strategic insights and practical tips to help you become a master of data resiliency, and prepare for the data breaches that are increasing likely to hit your organization. CIRCUMVENTION FOR APAR 'MA50336' :-----None DESCRIPTION OF PROBLEM FIXED FOR APAR 'MA50338' :-----When a virtual tape library type-model 3584-402 or 3584-403 isTo: ADSM-L < at > VM. Model abstract 3584-D42. 5. ORG will be going through forum software conversion and migration over the next several weeks. The IBM Data Server Driver for JDBC and SQLJ issues the following warning codes: +4204 Message text: Errors were encountered and tolerated as specified by the RETURN DATA UNTIL clause. Apply this fix to change the device recognition code to allow configuration to complete when device is to busy to respond normally to commands used to identify the device. The IBM® TS4500 Tape Library is designed to help midsized and large enterprises respond to cloud storage challenges. These are shown in IBM MQ component identifiers. GA32-0560-03 IBM System Storage TS3500 Tape Library. 64. Obtain the UpdateXpress CD. . MARIST. Some were drive problems. This section defines failure ID (FID) messages that are generated by 3592 tape drives in the TS3500 tape library. The previous support included coverage for a large number of newer technology tape and tape library devices. HYDIN0112W (OP0112) Device serial number device serial number has been made offline and/or unavailable by the TS7700 Engine with a reason code of reason code. Accessor {ACCESSOR} X home sensor was blocked when it should not have been. IBM System Storage TS3500 Tape Library Operator Guide, IBM 3584 Tape Library(1) - Free ebook download as PDF File (. Locate a 2 m (6. Use the information in this topic to perform this task. With the IBM 3584 tape solutions, Capacity on Demand is standard, the L22 and L52 base frames can come with only 56 or 117 of the available data cartridge slots activated, with the option to expand to 260 slots on demand. This section introduces all possible combinations of Sense Keys, Additional Sense Codes (ASC), and Additional Sense Code Qualifiers (ASCQ) that are reported by the 3584 Tape Library Enable the instance policy and prevent creating standard keys. 4. The document covers topics such as planning, hardware and software requirements, cluster design, network configuration, and troubleshooting. Also for: Ts1140, Ts1150, Eh7, Ts1160, Ts1155, Eh8. Configuration of equipment. A drive library interface failed. If more than one node is reporting this error, contact IBM technical support for assistance. The 3584 Tape Library supports the IBM TotalStorage LTO. Once was a known firmware problem. A drive requested a routine cleaning. See "identifying Device type" on page 260. If the drive is installed in a 3584 and you need operator information, use the TS3500 (3584) Operator Guide. As with the 3494 automated tape library, the. The IBM TotalStorage 3584 Tape Library is part of a family of tape library storage solutions designed for the large, unattended storage requirements from today's midrange systems to high-end open systems. Code updates are released to resolve . library is doing full backups and is thrashing over 100 bits of media continually with out any more problems. IBM 3584 Error code “Gripper Failed. 3584-L53 Data Control System from IBM 2-Year Warranty, Radwell Repairs - IBM 3584/TS3500 287-SLOT BASE FRAME (3592) Shop Online . If the gsk_status_code is CMS_ERR_ICSF_NOT_AVAILABLE, request that the NSSD administrator verify that ICSF is started. Cross-reference information. Gripper {GRIPPER} encountered a high current condition while retracting. . IBM System Storage TS3500 Tape Library with ALMS: Introduction and Planning Guide. Remote support for the TS4500 tape library involves the use of a Call Home feature to detect and solve problems. If we create the a partition on the 3584 without ALMS the Element IDs are. If the attached library is a 3584, ensure the device is assigned correctly to this virtual library at the 3584 Drive Assignment Web page. Failure ID (FID) messages are short codes that can be used by service technicians to isolate problems with the 3592 tape drive. The Call Home feature uses the integrated management console ( IMC. For Model L32, they are available as feature codes 1662 and 1660, respectively. Interface problem. Library is a 3584. The IBM TS3500 Command Line Interface (CLI) program can be used to access the TS3500 library from a CLI. that you can use the web interface. We did not > feel comfortable with the High-Density approach (i. Supplier Cage Code. clu versus CE1 xxxxx. 43Getting Started with your Dell Computer Vostro 3584 Setup, Specifications and Service Manual Find your Service Tag and Express Service Code Vostro 3584 Drivers and Downloads Warranty & Support Services. Dell PowerVault LTO5-140 Drive ID : IBM ULTRIUM-HH5. section introduces two ways that you can perform manual. Gripper {GRIPPER} encountered a high current condition while retracting. # step 1 - enable an instance policy, which prevents creating standard keys $ curl -X PUT "…A reset was done of the library and it seemed to be working fine - Various Drives came up with a disabled condition afterwards, but were reanabled, and are working fine now. 2728 xxxx. XS7. Find the reference code in the following list. 0015. 4. LDAP_NO_SUCH_OBJECT. Set when the tape drive is having problems reading data. This code must display on the tape drive order and also the Plant Install 3592 E05 in a 3584 feature (FC 9680) or Plant. ibm. Ibm 3584 Tape Library Manual need to replace the database file, you’ll retain all those efforts. Code requirements: IBM i 7. If you expand the list of medium changers, the troubled drive (drive 4) has a yellow exclamation point icon and when you. All TSM servers that access it are RH Linux so lin_tape is the driver.